
PLC
Select your PLC (In alphabetical order)
ABB
| Communication Driver | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| |
|
|
|
- | |
- | - |
Control Techniques
| Communication Driver | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| |
|
|
- | - | |||||
| |
|
|
- | - |
Control Technology Corp.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
CTC Binary Protocol
(2700 Series) |
- | - | - | - | - | - |
- For further information, refer to "Control Technology Corp. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
FANUC LTD.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
Power Mate Series
(Fanuc Power Mate Series, Fanuc Power Mate i Series, Fanuc Series) |
- | - | - |
- For further information, refer to "FANUC LTD. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Fatek Automation Corp.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
FB Series SIO
(FBs, FBe/FBn) |
- | - | - |
- For further information, refer to "Fatek Automation Corp. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Fuji Electric Co.,Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
MICREX-F Series SIO
(MICREX-F) |
- | - | - | - | |||||
|
MICREX-SX Series SIO
(MICREX-SX SPH) |
- | - | - | - | |||||
|
MICREX-SX Series Ethernet
(MICREX-SX SPH) |
- | - | - |
- For further information, refer to "Fuji Electric Co, Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
GE Intelligent Platforms
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 *6 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
Series 90-30/70 SNP
(Series 90-30, Series 90-70) |
- | - | - | - | |||||
|
Series 90-30/70 SNP-X
(Series 90-30, Series 90-70, VersaMax Micro) |
- | - | - | - | |||||
|
Series 90 Ethernet
(Series 90-30, Series 90-70R, PACSystem RX7i) |
- | - | - | - |
- For further information, refer to "GE Intelligent Platforms Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Hitachi Industrial Equipment Systems Co., Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | SSerial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
H Series SIO
(H, EH-150, MICRO-EH, Web Controller, EHV) |
- | - | - | ||||||
|
H Series Ethernet
(H, EH-150, MICRO-EH, Web Controlle, EHV) |
- | - | - |
- For further information, refer to "Hitachi Industrial Euipment System Co., Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Hitachi, Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
S10 Series SIO
(S10V, HIDIC-S10α, S10mini) |
- | - | - | - | - | ||||
|
S10V Series Ethernet
(S10V) |
- | - | - |
- For further information, refer to "Hitachi, Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
IEC Standard
| Communication Driver | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| - | - | - |
JTEKT Corporation
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| - | - | - | |||||||
| - | - | - |
- For further information, refer to "JTEKT Corporation Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
KEYENCE CORPORATION
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
KV-700/1000/3000/5000 CPU Direct
(KV-700/1000/3000/5000/5500) |
- | - | |||||||
|
Visual KV Series CPU Direct
(KV Series) |
- | - | - | - | |||||
|
KV-10_80RW/TW CPU Direct
(KV Series) |
- | - | - | ||||||
|
KV-700/1000/3000/5000 Ethernet
(KV-700/1000/3000/5000/5500) |
- | - | - |
- For further information, refer to "KEYENCE CORPORATION Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
KONNEX
| Communication Driver | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| - | - | - | - | - | - |
KOYO ELECTRONICS INDUSTRIES CO., LTD.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
KOSTAC/DL Series CCM SIO
(KOSTAC SG/SU/SZ/PZ3/SR, DL205/305/405, Direct Logic05/06) |
- | - | - | ||||||
|
KOSTAC/DL Series MODBUS TCP
(KOSTAC SU, DL205/405, Direct Logic05/06) |
- | - | - |
- For further information, refer to "KOYO ELECTRONICS INDUSTRIES CO., LTD. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Lenze
| Communication Driver | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| |
|
|
|
- | - |
LS Industrial Systems Co., Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
Master-K Series Cnet
(K1000S, K300S, K200S, K120S, K80S) |
- | - | - | ||||||
| |
|
*4,*6 |
|
|
|
- | - | ||
|
XGT Series Cnet
(XGK) |
- | - | - | ||||||
|
XGT Series FENet
(XGK) |
- | - | - |
- For further information, refer to "LS Industrial Systems Co., Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
MEIDENSHA CORPORATION
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
UNISEQUE Series Ethernet
(UNISEQUE) |
- | - | - | - |
- For further information, refer to "MEIDENSHA CORPORATION Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Mitsubishi Electric Corporation
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilinkk |
|---|---|---|---|---|---|---|---|---|---|
|
A Series CPU Direct
(MELSEC AnA, MELSEC AnN, MELSEC Q (A mode)) |
- | - | |||||||
|
A Series Computer Link
(MELSEC AnA, MELSEC AnN, MELSEC Q (A mode), MELSEC QnA) |
- | - | |||||||
|
Q Series CPU Direct
(MELSEC Q) |
- | - | |||||||
|
Q/QnA Serial Communication
(MELSEC Q, MELSEC QnA, MELSEC L) |
- | - | |||||||
|
QUTE Series CPU Direct
(MELSEC Q) |
- | - | |||||||
|
QnA Series CPU Direct
(MELSEC QnA) |
- | - | |||||||
|
FX Series CPU Direct
(MELSEC FX) |
- | - | |||||||
|
FX Series Computer Link
(MELSEC FX) |
- | - | |||||||
|
A Series Ethernet
(MELSEC A) |
- | - | - | - | |||||
|
Q/QnA Series Ethernet
(MELSEC Q, MELSEC QnA, MELSEC L) |
- | - | - | ||||||
|
Q Series QnU CPU Ethernet
(MELSEC Q) |
- | - | - | ||||||
|
FX Series Ethernet
(MELSEC FX) |
- | - | - |
- For further information, refer to "Mitsubishi Electric Corporation Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Mitsubishi Heavy Industries, Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
DIASYS Netmation MODBUS TCP
(DIASYS Netmation) |
- | - | - | - | |||||
|
MHI STEP3 Ethernet
(UP/V) |
- | - | - | - | - |
- For further information, refer to "Mitsubishi Heavy Industries, Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
OMRON Corporation
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multi Link |
|---|---|---|---|---|---|---|---|---|---|
|
C/CV Series HOST Link
(SYSMAC C/α/CV) |
- | - | |||||||
|
CS/CJ Series HOST Link
(SYSMAC CS1/CJ1/CJ2/CP1/CP1E) |
- | ||||||||
|
CS/CJ Series Ethernet
(SYSMAC CS/CJ1/CJ2/CP1) |
- | - | |||||||
| - | - | - |
- For further information, refer to "OMRON Corporation Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Panasonic Electric Works SUNX Co., Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, make sure to refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
FP Series Computer Link SIO
(FP) |
- | - |
- For further information, refer to "Panasonic Electric Works SUNX Co., Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Rockwell Automation, Inc.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
DF1
(SLC500, PLC-5, ControlLogix, MicroLogix, CompactLogix) |
- | - | |||||||
|
DH-485
(SLC500, ControlLogix, MicroLogix) |
- | - | - | - | |||||
|
EtherNet/IP
(SLC500, PLC-5, ControlLogix, MicroLogix, CompactLogix) |
- | - | - |
- For further information, refer to "Rockwell Automation, Inc. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Saia-Burgess Controls Ltd.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
SAIA S-Bus SIO
(PCD1, PCD2, PCD3, PCD4, PCD6) |
- | - | - | - |
- For further information, refer to "Saia-Burgess Controls Ltd. Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Schneider Electric SA
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
Uni-Telway
(Nano, Micro, Premium) |
- | - | - | ||||||
|
MODBUS SIO Master
(Micro, Premium, Twido, Quantum, Momentum) |
- | - | - | ||||||
|
MODBUS Slave (Serial)
(MODBUS communication devices) |
- | - | - | ||||||
|
MODBUS TCP Master
(Premium, Quantum) |
- | - | - | ||||||
|
MODBUS Slave (Ethernet)
(MODBUS communication devices) |
- | - | - |
- For further information, refer to "Schneider Electric SA Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Sharp Manufacturing Systems Corporation
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
JW Series Computer Link SIO
(JW10, JW20H, JW30H, JW50H, JW70H, JW100, JW300) |
- | - | - | - | |||||
|
JW Series Computer Link Ethernet
(JW30H, JW300) |
- | - | - |
- For further information, refer to "Sharp Manufacturing Systems Corporation Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
SICK AG
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
*4,*6 |
- | - |
- For further information, refer to "SICK AG Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Siemens AG
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
SIMATIC S7 MPI Direct
(SIMATIC S7-200/S7-300/S7-400) |
- | - | - | ||||||
|
SIMATIC S7 3964(R)/RK512
(SIMATIC S7-300/S7-400) |
- | - | - | ||||||
|
SIMATIC S5 CPU Direct
(90U - 115U Series, 135U/155U Series) |
- | - | - | ||||||
|
SIMATIC S5 3964(R)
(SIMATIC S5 Series) |
- | - | - | ||||||
|
SIMATIC S7 Ethernet★
(SIMATIC S7-200/S7-300/S7-400/ S7-1200, LOGO! Series) |
- | - | - | ||||||
| |
|
|
|
- | |
- | - |
- For further information, refer to "Siemens AG Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Siemens Building Technologies
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
SAPHIR SIO
(SAPHIR) |
- | - | - |
- For further information, refer to "Siemens Building Technologies Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
TOSHIBA CORPORATION
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
|
Computer Link SIO
(T Series, V Series, EX Series) |
- | - | - | - | |||||
|
Computer Link Ethernet
(T Series, V Series) |
- | - | - |
- For further information, refer to "TOSHIBA CORPORATION Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
TOSHIBA MACHINE CO., LTD.
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink |
|---|---|---|---|---|---|---|---|---|---|
| - | - |
- For further information, refer to "TOSHIBA MACHINE CO., LTD connection manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
YASKAWA Electric Corporation
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink | Sample |
|---|---|---|---|---|---|---|---|---|---|---|
|
MEMOBUS SIO
(Control Pack, MP900, MP2000, MEMOCON GL, MEMOCON SC, MEMOCON Micro) |
- | - | - | - | ||||||
|
MP Series SIO (Extension)
(MP2000) |
- | - | - | |||||||
| - | - | - | - | |||||||
|
|
- |
- For further information, refer to YASKAWA Electric Corporation Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.
Yokogawa Electric Corporation
| Communication Driver * The lower line in brackets shows connected series/device names. For detailed model numbers, refer to "Device/PLC Connection Manual". | GP 4000 | GP 4000M | GP 4100 | GP 3000 | GP 3000H | LT 3000 | PL/PS 3000 (WinGP) | Pass Through | Serial Multilink | Sample |
|---|---|---|---|---|---|---|---|---|---|---|
|
Personal Computer Link SIO
(FA-M3, FCN, FCJ) |
- | |||||||||
|
MODBUS SIO Master
(FCN, FCJ) |
- | - | - | - | - | |||||
|
Personal Computer Link Ethernet
(FA-M3) |
- | - | ||||||||
|
MODBUS TCP Master
(FCN, FCJ) |
- | - | - | - | - |
- For further information, refer to "Yokogawa Electric Corporation Connection Manual".
- Transfer Driver names with a symbol "★" require you to update the driver. Go to the download page after clicking a Transfer Driver name.




